444

Fabric OS Message Reference

53-1002749-01

FW-1039

5

FW-1039

Message

<Label>, is above high boundary(High=<High value>, Low=<Low value>). Current value
is <Value> <Unit>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the receive power value of the small form-factor pluggable (SFP) has risen above the high
boundary. The receive performance area measures the amount of incoming laser to help you determine
whether the SFP is in good working condition. If the counter often exceeds the threshold, the SFP is
deteriorating.

Recommended

Action

Replace the SFP before it deteriorates.

FW-1040

Message

<Label>, is between high and low boundaries(High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the receive power value of the small form-factor pluggable (SFP) has changed from a
value outside of the acceptable range to a value within the acceptable range. The receive performance
area measures the amount of incoming laser to help you determine whether the SFP is in good working
condition. If the counter often exceeds the threshold, the SFP is deteriorating.

Recommended

Action

No action is required. Respond to this message as is appropriate to the particular policy of the end-user
installation.

FW-1041

Message

<Label>, value has changed(High=<High value>, Low=<Low value>). Current value is
<Value> <Unit>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the transmit power value of the small form-factor pluggable (SFP) has changed. The
transmit performance area measures the amount of outgoing laser to help you determine whether the
SFP is in good working condition. If the counter often exceeds the threshold, the SFP is deteriorating.

Recommended

Action

Transmitting laser fluctuations usually indicates a deteriorating SFP. If the message persists, replace the
SFP.