Sulb-1032, Sulb-1033, Sulb-1034 – Dell POWEREDGE M1000E User Manual

Page 860

Advertising
background image

838

Fabric OS Message Reference

53-1002749-01

SULB-1032

5

Recommended

Action

Wait for the operation to complete.

SULB-1032

Message

Relocating an internal firmware image on the CP.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that the switch has started firmware download to the co-CPU.

Recommended

Action

Wait for the operation to complete.

SULB-1033

Message

Switch has completed relocating the internal firmware image.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

WARNING

Probable Cause

Indicates that the firmware download process has completed normally on the switch.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. Run the switchShow command to
make sure the switch is enabled.

SULB-1034

Message

Relocation of internal image timed out.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

ERROR

Probable Cause

Indicates that there may be an error caused by the switch initialization issue after the internal image is
relocated. It may also be caused by an internal Ethernet issue or by a persistent storage hardware
failure.

Recommended

Action

Reboot the switch. This will cause the internal image to be relocated again. Use the
firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your
switch service provider.

Advertising