778

Fabric OS Message Reference

53-1002749-01

SPC-2001

5

SPC-2001

Message

S<slot number containing Encryption Engine>, <module name>: Crypto error asserted
by Vader/OB1 0x<Reason>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that Crypto error is asserted by the Field-Programmable Gate Array (FPGA).

Recommended

Action

No action is required.

SPC-2002

Message

S<slot number containing Encryption Engine>, <module name>: Tamper Event: Crypto
subsystem cover tampered.

Message Type

LOG

Severity

CRITICAL

Probable Cause

Indicates that the Crypto subsystem cover is tampered. The encryption engine is zeroized.

Recommended

Action

Execute the cryptocfg --initEE and cryptocfg --regEE commands.

SPC-2003

Message

S<slot number containing Encryption Engine>, <module name>: Data Disable status:
0x<DisableStatus>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the data disable signal status.

Recommended

Action

No action is required.