Fabric OS Message Reference

383

53-1002749-01

FICN-1030

5

FICN-1030

Message

HostDiskIng:FICON Purge received:Path=0x<VEPortNumber HostDomain HostPort
DeviceDomain><DevicePort LPAR CUADDR DeviceAddr>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates an active disk emulation device received a FICON Purge Path from the channel.

Recommended

Action

If there was an unexpected job failure or I/O error associated with this event, contact your vendor's
customer support for assistance.

FICN-1031

Message

HostDiskIng:FICON System Reset received on Path=0x<VEPortNumber HostDomain
HostPort DeviceDomain><DevicePort LPAR><CUADDR>**.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates the FICON channel sent a System Reset to the disk control unit.

Recommended

Action

No action is required. The MVS system was either set to initial program load (IPL) or performing error
recovery.

FICN-1032

Message

HostDiskIng:XRC Read Channel Extender Capabilities detected on Path:
0x<VEPortNumber HostDomain HostPort DeviceDomain><DevicePort LPAR CUADDR
DeviceAddr>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the eXtended Remote Copy (XRC) System Data mover was restarted to discover the
capabilities of the channel extension equipment.

Recommended

Action

No action is required. This is a part of the XRC initialization.