Fcr-1072, Fcr-1073, Fcr-1074 – Dell POWEREDGE M1000E User Manual

Page 387

Advertising
background image

Fabric OS Message Reference

365

53-1002749-01

FCR-1072

5

FCR-1072

Message

Port <port number> is changed from FCR port to non FCR port.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the port is no longer an EX_Port or VEX_Port.

Recommended

Action

No action is required.

FCR-1073

Message

Switch with domain ID <domain ID> in fabric <fabric ID> has lower limit of LSAN
Zones supported.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that an older version switch in the backbone or edge that supports a different limit of logical
storage area network (LSAN) zones was detected.

Recommended

Action

Use the fcrResourceShow command on all Fibre Channel Routers in the Meta-SAN to find lowest
supported LSAN zone limits. Ensure the total number of LSAN zones in the Meta-SAN are within the
lowest supported limit of LSAN zones.

FCR-1074

Message

HA sync lost as remote CP supports only <LSAN Count> LSAN Zones.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the remote control processor (CP) has older firmware, which supports a lower number of
logical storage area network (LSAN) zones. This is causing the loss of high availability (HA) sync.

Recommended

Action

Keep the number of LSAN zones to the lower limit of the two CPs or upgrade the remote CP.

Advertising