Sulb-1017, Sulb-1018 – Dell POWEREDGE M1000E User Manual

Page 856

Advertising
background image

834

Fabric OS Message Reference

53-1002749-01

SULB-1017

5

Recommended

Action

Run the firmwareDownloadStatus command for more information.

Refer to the Fabric OS Troubleshooting Guide for troubleshooting information.

SULB-1017

Message

Firmwaredownload failed in slot <Slot number>.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

ERROR

Probable Cause

Indicates that the firmwareDownload command failed on the specified blade. The error may be caused
by the inconsistent application processor (AP) blade firmware stored on the active CP. It may also be
caused by an internal Ethernet issue or by a persistent storage hardware failure.

Recommended

Action

Run the slotShow command. If the blade is in the FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmware download. If the blade is stuck in the LOADING
state, remove and re-insert the blade to trigger another firmware download. If the problem persists,
contact your switch service provider.

SULB-1018

Message

Firmwaredownload timed out in slot <Slot number>.

Message Type

AUDIT | LOG

Class

FIRMWARE

Severity

ERROR

Probable Cause

Indicates that there may be error caused by the blade initialization issue after the new firmware is
downloaded and the blade is rebooted. The error may also be caused by an internal Ethernet issue or by
a persistent storage hardware failure.

Recommended

Action

Run the slotShow command. If the blade is in the FAULTY state, run the slotPowerOff and
slotPowerOn commands to trigger another firmware download to the blade. If the blade is stuck in the
LOADING state, remove and re-insert the blade to trigger another firmware download. If the problem
persists, contact your switch service provider.