BL-1003

5

BL-1003

Message

Faulting blade in slot <slot number>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates a faulty blade in the specified slot.

Recommended

Action

Make sure that the blade is seated correctly.

If the blade is seated correctly, execute the diagPost command to make sure that Power-On Self-Test
(POST) is enabled; then power cycle the blade using the slotPowerOff and slotPowerOn commands or
have the blade's ejector switch cycled to run POST and verify that the blade does not have any hardware
problems.

If the message persists, replace the blade.

BL-1004

Message

Suppressing blade fault in slot <slot number>.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the specified blade experienced a failure but was not faulted due to a user setting.

Recommended

Action

Execute the diagPost command to make sure that Power-On Self-Test (POST) is enabled; then power
cycle the blade using the slotPowerOff and slotPowerOn commands or have the blade's ejector switch
cycled to run POST and verify that the blade does not have any hardware problems.

If the message persists, replace the blade.

BL-1006

Message

Blade <slot number> NOT faulted. Peer blade <slot number> experienced abrupt
failure.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the errors (mostly synchronization errors) on the specified blade are harmless. Probably,
the standby control processor (CP) blade connected to the active CP blade has experienced transitory
problems.

Recommended

Action

Execute the haShow command to verify that the standby CP is healthy. If the problem persists, remove
and reinstall the faulty blade.

If the standby CP was removed or faulted by user intervention, no action is required.