Fcph messages, Fcph-1001, Fcph-1002 – Dell POWEREDGE M1000E User Manual

Page 365: Fcph-1003

Advertising
background image

Fabric OS Message Reference

343

53-1002749-01

FCPH-1001

5

FCPH Messages

FCPH-1001

Message

<function>: <failed function call> failed, out of memory condition.

Message Type

FFDC | LOG

Severity

CRITICAL

Probable Cause

Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel driver
instance.

The function value can only be fc_create. This function creates a Fibre Channel driver instance.

The failed function call can only be kmalloc_wrapper, which has failed. This function call is for kernel
memory allocation.

Recommended

Action

A non-bladed switch will automatically reboot. For a bladed switch, the active CP blade will automatically
fail over and the standby CP will become the active CP.

FCPH-1002

Message

Port <Port Number> has been disabled since switch requires authentication when
device authentication policy is set to ON.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates a device that does not support authentication has tried to log in to the switch when the device
authentication policy is in ON status on the switch.

Recommended

Action

Enable the authentication on the device or set the device authentication status to PASSIVE/OFF on the
switch if it is not mandatory. Use the authUtil command to change the device authentication policy.

FCPH-1003

Message

New port <Port Number> has same Port WWN as old port <Port Number> as part of
duplicate Port WWN detection policy.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the specified new port has the same Port World Wide Name (PWWN) as the old port.

Recommended

Action

No action is required.