Mstp messages, Mstp-1001, Mstp-1002 – Dell POWEREDGE M1000E User Manual

Page 646: Mstp-1003

Advertising
background image

624

Fabric OS Message Reference

53-1002749-01

MSTP-1001

5

MSTP Messages

MSTP-1001

Message

<message>: <message>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the system has failed to allocate memory.

Recommended

Action

Check the memory usage on the switch using the memShow command.

Restart or power cycle the switch.

MSTP-1002

Message

<message>: <message>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the system has failed to initialize.

Recommended

Action

Restart or power cycle the switch.

MSTP-1003

Message

<message>: <message>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates a connection, transfer, or receiving error in the socket.

Recommended

Action

If this is a bladed switch, execute the haFailover command. If the problem persists or if this is a
non-bladed switch, download a new firmware version using the firmwareDownload command.

Advertising