Em-1047, Em-1048, Em-1049 – Dell POWEREDGE M1000E User Manual

Page 311

Advertising
background image

Fabric OS Message Reference

289

53-1002749-01

EM-1047

5

Recommended

Action

If the blade ID listed is incorrect, the field-replaceable unit (FRU) header for the blade is corrupted and
the blade must be replaced.

If the error is due to the platform, the blade ID listed is not supported for that platform (CP) type. Remove
the blade from the chassis.

If the error is due to the backplane, the CP type (CP256) is not supported on that chassis (backplane
revision D2). Remove the blade from the chassis.

If the error is due to the switch configuration, the logical switch configuration of the blade is incorrect.
Execute the lscfg command to correct the switch or port configuration for the ports on the blade.

EM-1047

Message

CP in slot <slot number> not faulty, CP ERROR deasserted.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the control processor (CP) is no longer faulted. This message usually follows the EM-1033
message. The new standby CP is in the process of restarting and has turned off the CP_ERR signal.

Recommended

Action

No action is required.

EM-1048

Message

<FRU Id> I2C access recovered: state <current state>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the Inter-Integrated Circuit (I2C) bus problems have been resolved and I2C access to the
field-replaceable unit (FRU) has become available again.

Recommended

Action

No action is required. The EM-1048 message is displayed when the EM-1029 error is resolved.

EM-1049

Message

FRU <FRU Id> insertion detected.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a field-replaceable unit (FRU) of the type and location specified by the FRU ID value was
detected as having been inserted into the chassis.