Fabric OS Message Reference

53-1002749-01

BM-1055

5

BM-1055

Message

Firmwaredownload timed-out for AP. Faulting switch.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that firmware download on the application processor (AP) blade has failed.

Recommended

Action

Execute the slotPowerOff and slotPowerOn commands or reseat the affected blade.

BM-1056

Message

AP is not configured. Persistently disabling all ports on the switch.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the policy of the specified switch is to persistently disable all ports the first time the AP is
detected. This may be caused by one of the following reasons:

The AP was detected for the first time on this switch.

The switch was configured under a different mode.

Recommended

Action

Configure the switch to persistently enable all ports.

BM-1058

Message

Download of AP firmware failed for the switch. Reissue firmwaredownload to
recover.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the automatic firmware upgrade on the application processor (AP) failed because the
firmware version running on the AP was detected to be different from the system firmware.

Recommended

Action

Execute the firmwareDownload command to recover the AP.