Mfic messages, Mfic-1001, Mfic-1002 – Dell POWEREDGE M1000E User Manual

Page 633: Mfic-1003

Advertising
background image

Fabric OS Message Reference

611

53-1002749-01

MFIC-1001

5

MFIC Messages

MFIC-1001

Message

failure at sysmod_scn registry rc= <failure reason>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates the system is temporarily out of resources.

Recommended

Action

No action is required; this message is often transitory.

If the message persists, run the reboot or the haFailover command (if applicable).

If the message persists, run the supportFtp command (as needed) to set up automatic FTP transfers;
then run the supportSave command and contact your switch service provider.

MFIC-1002

Message

Chassis FRU header not programmed for switch NID, using defaults (applies only to
FICON environments).

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that custom switch node descriptor (NID) fields have not been programmed in nonvolatile
storage. The default values are used. The Switch NID is used only in the following SB ELS frames:
Request Node Identification Data (RNID) and Registered Link Incident Record (RLIR). The use of SB-3
link incident registration and reporting is typically limited to FICON environments.

Recommended

Action

No action is required if SB-3 link incident registration and reporting is not used by the host or if default
values are desired for the switch node descriptor fields.

MFIC-1003

Message

Effective Insistent domain ID for the fabric changed from <state> to <state>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that one or more switches joined the fabric with an insistent domain ID (IDID) mode setting that
is different from the current effective IDID mode for the fabric. This message also occurs when the IDID
for the fabric has been turned on or off. The possible values for the state are "On" and "Off".