Cdr-1022, Cdr-1028 – Dell POWEREDGE M1000E User Manual

Page 235

Advertising
background image

Fabric OS Message Reference

213

53-1002749-01

CDR-1022

5

CDR-1022

Message

S<slot number>,P<port number>(<blade port number>): Link Timeout on External port,
ftx=<frame transmitted> tov=<real timeout value> (><expected timeout value>)
vc_no=<vc number> crd(s)lost=<Credit(s) lost>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that above-normal errors are observed in hardware that may or may not impact the data traffic.

Recommended

Action

When this error is observed persistently, power cycle the specified blade using the slotPowerOff and
slotPowerOn commands. If the problem persists, replace the blade.

CDR-1028

Message

Detected excessive Link resets on the port in a second. Slot <slot number>, Port
<port number>(<blade port number>).

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that the port received excessive link resets from peer port within 1 second and that exceeded
threshold.

Recommended

Action

When this error is observed persistently, change the small form-factor pluggable (SFP) transceiver or the
cable on the peer port to which this port is connected.

Advertising