Ssmd-1207, Ssmd-1208, Ssmd-1209 – Dell POWEREDGE M1000E User Manual

Page 837

Advertising
background image

Fabric OS Message Reference

815

53-1002749-01

SSMD-1207

5

SSMD-1207

Message

QoS failed programming interface 0x<Interface ID> Default CoS.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface Default CoS feature.

Recommended

Action

Delete and reapply the QoS interface Default CoS policy using the qos cos command.

If the problem persists, restart or power cycle the switch.

SSMD-1208

Message

QoS failed programming interface 0x<Interface ID> Trust.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface Trust feature.

Recommended

Action

Delete and reapply the QoS interface Trust policy using the qos trust cos command.

If the problem persists, restart or power cycle the switch.

SSMD-1209

Message

QoS failed programming interface 0x<Interface ID> CoS Mutation map.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that DCE SSM encountered an unexpected error in programming the dataplane ASIC for
enforcing the interface CoS Mutation mapping feature.

Recommended

Action

Delete and reapply the QoS interface CoS Mutation policy using the qos cos-mutation command.

If the problem persists, restart or power cycle the switch.