Fabric OS Message Reference

843

53-1002749-01

SWCH-1001

5

SWCH Messages

SWCH-1001

Message

Switch is not in ready state - Switch enable failed, switch status= 0x<switch
status>, c_flags = 0x<switch control flags>.

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the switch is enabled before it is ready.

Recommended

Action

If the message persists, execute the supportFtp command (as needed) to set up automatic FTP
transfers; then execute the supportSave command and contact your switch service provider.

SWCH-1002

Message

Security violation: Unauthorized device <wwn name of device> tries to flogin to
port <port number>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that the specified device is not present in the authorized profile list.

Recommended

Action

Verify that the device is authorized to log in to the switch. If the device is authorized, execute the
secPolicyDump command to verify whether the World Wide Name (WWN) of the specified device is
listed. If it is not listed, execute the secPolicyAdd command to add this device to an existing policy.

SWCH-1003

Message

Slot ENABLED but Not Ready during recovery, disabling slot = <slot number>(<return
value>).

Message Type

LOG

Severity

ERROR

Probable Cause

Indicates that the slot state has been detected as inconsistent during failover or recovery.

Recommended

Action

For a bladed switch, execute the slotPowerOff and slotPowerOn commands to power cycle the blade.

For a non-bladed switch, reboot or power cycle the switch.