Ts messages, Ts-1001, Ts-1002 – Dell POWEREDGE M1000E User Manual

Page 887

Advertising
background image

Fabric OS Message Reference

865

53-1002749-01

TS-1001

5

TS Messages

TS-1001

Message

NTP Query failed: <error code>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that a Network Time Protocol (NTP) query to the configured external clock server failed. Local
clock time on the principal or primary fabric configuration server (FCS) switch is used for fabric
synchronization.

This message may be logged during temporary operational issues such as IP network connection issues
to the external clock server. If the message does not recur, it can be ignored.

Recommended

Action

Execute the tsClockServer command to verify that the configured external clock server is available and
functional. If that external clock server is not available, choose another clock server.

TS-1002

Message

<Type of clock server used> Clock Server used instead of <Type of clock server
configured>: locl: 0x<Reference ID of LOCL> remote: 0x<Reference ID of external
clock server>.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates the fabric time synchronization was sourced from an alternate clock server instead of the
configured clock server. The clock server used can be one of the following type:

LOCL - Local clock on the principal or primary FCS switch.

External - External Network Time Protocol (NTP) server address configured.

This message may be logged during temporary operational issues such as IP network connection issues
to the external clock server or the fabric is configured for external time synchronization but the principal
or primary fabric configuration server (FCS) does not support the feature. If the message does not recur,
it can be ignored.

Recommended

Action

Execute the tsClockServer command to verify that the principal or primary FCS switch has the clock
server IP configured correctly, and the configured clock server is accessible to the switch and functional.
If the principal or primary FCS does not support the feature, either choose a different switch for the role
or reset the clock server to LOCL.

Advertising