Cdr-1007, Cdr-1008, Cdr-1009 – Dell POWEREDGE M1000E User Manual

Page 231

Advertising
background image

Fabric OS Message Reference

209

53-1002749-01

CDR-1007

5

CDR-1007

Message

S<slot number>,C<chip index>: Internal link errors have been reported, no hardware
faults identified, continuing to monitor for errors: flt1:0x<fault1_cnt>,
flt2:0x<fault2_cnt> thresh1:0x<threshold_used>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that some errors were found in hardware that may or may not impact the data traffic.

Recommended

Action

No action is required.

CDR-1008

Message

S<slot number>,C<chip index>: HW ASIC Chip warning Level 1 type = 0x<chip error
type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.

CDR-1009

Message

S<slot number>,C<chip index>: HW ASIC Chip warning Level 2 type = 0x<chip error
type>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may or may
not degrade the data traffic.

Recommended

Action

Restart the system at the next maintenance window.