Fabric OS Message Reference

359

53-1002749-01

FCR-1054

5

FCR-1054

Message

Port <port number> received ILS <command> of incorrect size (<actual payload
size>); valid ILS size is <expected payload size>.

Message Type

LOG

Severity

WARNING

Probable Cause

Indicates that an internal link service (ILS) IU of invalid size was received from the switch on the other
end of the link.

Recommended

Action

Check the error message log on the other switch using the errShow command for additional messages.

Check for a faulty cable or deteriorated small form-factor pluggable (SFP). Replace the cable or the SFP
if necessary.

Run the portLogDumpPort command on both the receiving and transmitting ports.

Run the fabStatsShow command on the transmitting switch.

If the message persists, collect switch information using the supportSave command, and contact your
switch service provider.

FCR-1055

Message

Switch with domain ID <domain ID> does not support backbone to edge imports.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a switch that does not support backbone-to-edge routing was detected in the backbone.
Edge-to-edge routing will work, but backbone-to-edge routing may fail.

Recommended

Action

No action is required if backbone-to-edge routing is not required. Otherwise, replace the switch with one
that supports backbone-to-edge routing.

FCR-1056

Message

Switch <switch WWN> with front domain ID <domain ID> does not support backbone to
edge imports.

Message Type

LOG

Severity

INFO

Probable Cause

Indicates that a switch that does not support backbone-to-edge routing is running in the MetaSAN.

Recommended

Action

No action is required if backbone-to-edge routing is not needed. Otherwise, replace the switch with one
that supports backbone-to-edge routing.