Ag-1004, Ag-1005, Ag-1006 – Dell POWEREDGE M1000E User Manual

Page 102: Ag-1007

Advertising
background image

26

Fabric OS Message Reference

53-1001767-01

AG-1004

2

Severity

WARNING

AG-1004

Message

<timestamp>, [AG-1004], <sequence-number>,, ERROR, <system-name>, Invalid

response to fabric login (FLOGI) request from the fabric for N_Port <port>.

Probable Cause

Indicates the fabric sent an invalid response to the FLOGI Extended Link Service (ELS) for the
specified N_Port.

Recommended

Action

Check the configuration of the fabric switch.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

ERROR

AG-1005

Message

<timestamp>, [AG-1005], <sequence-number>,, WARNING, <system-name>, FDISC

response was dropped because F_Port <port> is offline.

Probable Cause

Indicates the F_Port connected to the host is offline, which caused the FDISC response to drop.

Recommended

Action

Check the configuration of the host connected to the specified F_Port.

Severity

WARNING

AG-1006

Message

<timestamp>, [AG-1006], <sequence-number>,, INFO, <system-name>, Access Gateway

mode has been <msg>.

Probable Cause

Indicates Access Gateway mode has been enabled or disabled.

Recommended

Action

Run the ag --modeshow command to verify the current status of the Access Gateway mode.

Severity

INFO

AG-1007

Message

<timestamp>, [AG-1007], <sequence-number>,, WARNING, <system-name>, FLOGI

response not received for the N_Port

<port>

connected to the fabric.

Probable Cause

Indicates the N_Port connected to the fabric switch is not online. The specified N_Port has been
disabled.

Advertising