HIL-1104

45

HIL-1104

Message

<timestamp>, [HIL-1104], <sequence-number>,, ERROR, <system-name>, Blower <blower

number> faulted, <nominal voltage> (<measured voltage>) is below threshold.

Probable Cause

Indicates that the fan voltage is below threshold.

Recommended

Action

Run the psShow command to verify the power supply status.

Try to reseat the faulty fan field-replaceable units (FRUs) and power supply FRU to verify that they
are seated properly.

If the problem persists, replace the fan FRU or the power supply FRU as necessary.

Severity

ERROR

HIL-1105

Message

<timestamp>, [HIL-1105], <sequence-number>,, ERROR, <system-name>, Switch error,

<nominal voltage> (<measured voltage>) above threshold.

Probable Cause

Indicates that the switch voltage is above threshold. This message is specific to nonbladed
switches and is not applicable to the Brocade 24000 or 48000.

Recommended

Action

For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must
be replaced because these switches do not have field-replaceable units (FRUs).

For the Brocade 3900, replace the motherboard FRU.

For the Brocade 4100 , 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both
power supplies; if any other voltage is faulty, replace the entire switch.

Severity

ERROR

HIL-1106

Message

<timestamp>, [HIL-1106], <sequence-number>,, ERROR, <system-name>, Switch error,

<nominal voltage> (<measured voltage>) below threshold.

Probable Cause

Indicates that the switch voltage is below threshold. This message is specific to nonbladed
switches and is not applicable to the Brocade 24000 or 48000.

Recommended

Action

For the Brocade 200E, 3250, 3850, 4012, 4016, 4018, 4020, and 4024, the entire switch must
be replaced because these switches do not have field-replaceable units (FRUs).

For the Brocade 3900, replace the motherboard FRU.

For the Brocade 4100, 4900, 7500, and AP7600, if the 12 volt level is faulty, replace one or both
power supplies; if any other voltage is faulty, replace the entire switch.