Bl-1027, Bl-1028, Bl-1029 – Dell POWEREDGE M1000E User Manual

Page 144

Advertising
background image

68

Fabric OS Message Reference

53-1001767-01

BL-1027

7

Probable Cause

Indicates that an internal port went offline during the warm recovery of the switch. The switch will
reboot and start a cold recovery.

Recommended

Action

Collect supportSave information, then restart the switch and run the diagPost command to ensure
Power-On Self-Test (POST) is enabled. If the problem persists, replace the switch.

Severity

CRITICAL

BL-1027

Message

<timestamp>, [BL-1027], <sequence-number>,, CRITICAL, <system-name>, Blade in

slot <slot number> faulted, boot failed; status 0x<boot status> 0x<1250 0 boot

status> 0x<1250 1 boot status>.

Probable Cause

Indicates that the blade failed to boot properly.

Recommended

Action

Restart or power cycle the blade.

If the message persists, replace the blade.

Severity

CRITICAL

BL-1028

Message

<timestamp>, [BL-1028], <sequence-number>,, CRITICAL, <system-name>, Switch

faulted; internal processor was reset before switch init completed.

Probable Cause

Indicates that the switch's internal processor was reset before the initialization completed.

Recommended

Action

Restart or power cycle the switch.

If the message persists, replace the switch.

Severity

CRITICAL

BL-1029

Message

<timestamp>, [BL-1029], <sequence-number>,, INFO, <system-name>, All ports on the

switch will be reset as part of the firmware upgrade.

Probable Cause

Indicates that a recent firmware upgrade caused the switch's internal processor firmware to be
upgraded and resulted in the cold upgrade. As part of the upgrade, all the datapath elements were
reset.

Recommended

Action

No action is required.

Severity

INFO

Advertising