Message
<timestamp>, [BLL-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, ASIC
driver detected Slot <slot number> port <port number> as faulty (reason: <reason>)
Probable Cause
Indicates a blade regulation problem was reported on the specified slot number. The blade is
faulted.
The possible reason codes are as follows:
•
1 = Available buffer overflow
•
2 = Backend port buffer timeout
•
3 = Backend port got shut down
•
4 = Embedded port buffer timeout
•
5 = Excessive busy mini buffer
•
6 = Excessive RCC VC on E_Port
•
7 = Excessive RCC VC on FL_Port
•
8 = Fail detection buffer tag error
•
9 = Fail detection TX parity error
•
10 = EPI CMEM interrupt error
•
11 = CMI interrupt error
•
12 = Interrupt overrun
•
13 = FDET interrupt
•
14 = Interrupt suspended
•
15 = Filter LISTD error
•
16 = Unknown filter LIST error
•
17 = Wait for LPC open state
•
18 = Wait for Old port state
•
19 = Wait for Open init state
•
20 = TX parity error
•
21 = RAM parity error
•
22 = BISR or RAMINIT error
Recommended
Action
Make sure the blade is seated correctly. If the blade is seated correctly, restart or power cycle the
blade. Run the systemVerification command to verify that the blade does not have any hardware
problems. To run this command root access is required. Refer to the Fabric OS Command
Reference for more information on this command. If the message persists, replace the blade.