BLL System Messages

BLL-1000

Message

<timestamp>, [BLL-1000], <sequence-number>, FFDC, CRITICAL, <system-name>, ASIC

driver detected Slot <slot number> port <port number> as faulty (reason: <reason>)

Probable Cause

Indicates a blade regulation problem was reported on the specified slot number. The blade is
faulted.

The possible reason codes are as follows:

1 = Available buffer overflow

2 = Backend port buffer timeout

3 = Backend port got shut down

4 = Embedded port buffer timeout

5 = Excessive busy mini buffer

6 = Excessive RCC VC on E_Port

7 = Excessive RCC VC on FL_Port

8 = Fail detection buffer tag error

9 = Fail detection TX parity error

10 = EPI CMEM interrupt error

11 = CMI interrupt error

12 = Interrupt overrun

13 = FDET interrupt

14 = Interrupt suspended

15 = Filter LISTD error

16 = Unknown filter LIST error

17 = Wait for LPC open state

18 = Wait for Old port state

19 = Wait for Open init state

20 = TX parity error

21 = RAM parity error

22 = BISR or RAMINIT error

Recommended

Action

Make sure the blade is seated correctly. If the blade is seated correctly, restart or power cycle the
blade. Run the systemVerification command to verify that the blade does not have any hardware
problems. To run this command root access is required. Refer to the Fabric OS Command
Reference
for more information on this command. If the message persists, replace the blade.