background image

Fabric OS Message Reference

677

53-1001767-01

Chapter

113

AUDIT AN System Messages

AN-1003

Message

<timestamp>, [AN-1003], <sequence-number>,, WARNING, <system-name>, Slot <slot

number>, port <port number within slot number> is a latency bottleneck.

<percentage of seconds affected by latency bottlenecking> percent of last

<observation period over which the percentage of affected seconds is reported>

seconds were affected by this condition.

Probable Cause

For an F_Port, it indicates that the attached device is slow in responding to frames going out of this
port. This latency may be inherent in the device or due to heavy workload on the device. For an
E_Port, it indicates a downstream primary bottleneck.

Recommended

Action

Find the Top Talkers in the egress direction from this port and apply Ingress Rate Limiting to one or
more of them.

Severity

WARNING

AN-1004

Message

<timestamp>, [AN-1004], <sequence-number>,, WARNING, <system-name>, Slot <slot

number>, port <port number within slot number> is a congestion bottleneck.

<percentage of seconds affected by congestion bottlenecking> percent of last

<observation period over which the percentage of affected seconds is reported>

seconds were affected by this condition.

Probable Cause

Indicates that the volume of outgoing traffic at this port is too high for the capacity of the link.

Recommended

Action

Add more capacity on the path, using trunk links if possible.

Severity

WARNING

AN-1005

Message

<timestamp>, [AN-1005], <sequence-number>,, WARNING, <system-name>, Slot <slot

number>, port <port number within slot number> has <bottleneck type> bottleneck

cleared.

Probable Cause

Indicates that the bottleneck was cleared on the port.

Recommended

Action

No action is required.

Severity

WARNING