Cdr-1004, Cdr-1005, Cdr-1006 – Dell POWEREDGE M1000E User Manual
Page 164
88
Fabric OS Message Reference
53-1001767-01
CDR-1004
12
Severity
CRITICAL
CDR-1004
Message
<timestamp>, [CDR-1004], <sequence-number>, FFDC, ERROR, <system-name>, <slot
number>, <chip index>: invalid DMA ch pointer, chan:<Channel number>,
good_addr:0x<Good address>, bad_addr:0x<Bad address>.
Probable Cause
Indicates an internal error in the application specific integrated circuit (ASIC) hardware that may
degrade data traffic.
Recommended
Action
Whenever this error occurs, restart the system at the next maintenance window. If the problem
persists, replace the blade.
Severity
ERROR
CDR-1005
Message
<timestamp>, [CDR-1005], <sequence-number>,, WARNING, <system-name>, <slot
number>, <port number><blade port number>: at next port state change, best effort
QOS will be turned off automatically due to best effort is no longer supported
under this configuration.
Probable Cause
Indicates QoS will be turned off automatically at the next port state change because best effort is
no longer supported on a 4G platform or 8G platform long distance port.
Recommended
Action
No action is required.
Severity
WARNING
CDR-1006
Message
<timestamp>, [CDR-1006], <sequence-number>,, WARNING, <system-name>, <slot
number>, <port number><blade port number>: QOS overwrites portcfglongdistance
vc_translation_link_init. ARB will be used on the link.
Probable Cause
Indicates QoS overwrites the portcfglongdistance vc_translation_link_init 0 choice. ARB will be
used on the link.
Recommended
Action
No action is required.
Severity
WARNING