Sec-1192, Sec-1193, Sec-1194 – Dell POWEREDGE M1000E User Manual

Page 620

Advertising
background image

544

Fabric OS Message Reference

53-1001767-01

SEC-1192

90

Recommended

Action

Determine whether the host IP address specified in the message can be used to manage the fabric
through an HTTP connection. If so, add the host IP address to the HTTP policy of the fabric. If the
host is not allowed access to the fabric, this is a valid violation message and an unauthorized entity
is trying to access your fabric. Take appropriate action, as defined by your enterprise security policy.

Severity

INFO

SEC-1192

Message

<timestamp>, [SEC-1192], <sequence-number>,, INFO, <system-name>, Security

violation: Login failure attempt via

<connection method>

.

Probable Cause

Indicates a serial or modem login security violation was reported. An incorrect password was used
while trying to log in through a serial or modem connection; the login failed.

Recommended

Action

Use the correct password.

Severity

INFO

SEC-1193

Message

<timestamp>, [SEC-1193], <sequence-number>,, INFO, <system-name>, Security

violation: Login failure attempt via <connection method>. IP Addr: <IP address>

Probable Cause

Indicates a specified login security violation was reported. The incorrect password was used while
trying to log in through the specified connection method; the login failed.

Recommended

Action

The error message lists the violating IP address. Verify that this IP address is being used by a valid
switch admin. Use the correct password.

Severity

INFO

SEC-1194

Message

<timestamp>, [SEC-1194], <sequence-number>,, WARNING, <system-name>, This switch

does not have all the required PKI objects correctly installed.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

WARNING

Advertising