Bl-1010, Bl-1011, Bl-1012 – Dell POWEREDGE M1000E User Manual

Page 138

Advertising
background image

62

Fabric OS Message Reference

53-1001767-01

BL-1010

7

If the message persists, replace the blade.

Severity

CRITICAL

BL-1010

Message

<timestamp>, [BL-1010], <sequence-number>,, WARNING, <system-name>, Blade in slot

<slot number> inconsistent with the hardware settings.

Probable Cause

Indicates that a failover occurred while some hardware changes were being made on the previously
active control processor (CP) (such as changing the domain ID).

Recommended

Action

No action is required. This blade has been reinitialized. Because reinitializing a blade is a disruptive
operation and can stop I/O traffic, you might have to stop and restart the traffic during this process.

Severity

WARNING

BL-1011

Message

<timestamp>, [BL-1011], <sequence-number>, FFDC, CRITICAL, <system-name>, Busy

with emb-port int. for chip <chip number> in minis <minis number> on blade <slot

number>, chip int. is disabled. interrupt status=0x<interrupt status>.

Probable Cause

Indicates that too many interrupts in the embedded port caused the specified chip to be disabled.
The probable cause is too many abnormal frames; the chip is disabled to prevent the control
processor (CP) from becoming too busy.

Recommended

Action

Make sure to capture the console output during this process.

Check for a faulty cable, small form-factor pluggable (SFP), or device attached to the specified port.

Run the systemVerification command to verify that the blade or switch does not have hardware
problems. To run this command root access is required.

Run the diagPost command to ensure that Power-On Self-Test (POST) is enabled.

On a bladed switch, run the slotPowerOff and slotPowerOn commands.

On a nonbladed switch, restart or power cycle the switch.

If the message persists, replace the blade or the (nonbladed) switch.

Severity

CRITICAL

BL-1012

Message

<timestamp>, [BL-1012], <sequence-number>,, ERROR, <system-name>, bport <port

number> port int. is disabled. status=0x<interrupt status> Port <port number> will

be re-enabled in 1 minute.

Advertising