Fabric OS Message Reference

53-1001767-01

ICPD-1005

52

Recommended

Action

Enable the iSNS Client service on a single switch in the fabric using the fosConfig command. Refer
to the Fabric OS Command Reference for more information on this command.

Severity

WARNING

ICPD-1005

Message

<timestamp>, [ICPD-1005], <sequence-number>,, WARNING, <system-name>, iSCSI

configuration between local switch (<local domain id>) and peer (<peer domain id>)

is out of sync. iSCSI login is not allowed.

Probable Cause

Indicates that iSCSI switches in the fabric have different configurations in AUTH, VT, or DD.

Recommended

Action

Synchronize the configuration in the fabric using the iscsiCfg command. Refer to the Fabric OS
Command Reference
for more information on this command.

Severity

WARNING

ICPD-1006

Message

<timestamp>, [ICPD-1006], <sequence-number>,, INFO, <system-name>, iSCSI service

is

<status>

on the switch.

Probable Cause

Indicates the iSCSI service is enabled or disabled on the switch.

Recommended

Action

No action is required.

Severity

INFO

ICPD-1007

Message

<timestamp>, [ICPD-1007], <sequence-number>,, INFO, <system-name>, iSNSC service

is

<status>

on the switch.

Probable Cause

Indicates the iSNSC service is enabled or disabled on the switch.

Recommended

Action

No action is required.

Severity

INFO

ICPD-1008

Message

<timestamp>, [ICPD-1008], <sequence-number>,, INFO, <system-name>, iSCSI switch

(<domain id>) is <status>.

Probable Cause

Indicates the iSCSI switch is reachable or unreachable.