Anv-1004, Anv-1005, Anv-1006 – Dell POWEREDGE M1000E User Manual

Page 130: Anv-1007

Advertising
background image

54

Fabric OS Message Reference

53-1001767-01

ANV-1004

5

ANV-1004

Message

<timestamp>, [ANV-1004], <sequence-number>,, ERROR, <system-name>, <slot

number>,<chip index>: Invalid DMA ch pointer, chan:<Channel number>,

good_addr:0x<Good address> bad_addr:0x<Bad address>.

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that may
degrade data traffic.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.

Severity

ERROR

ANV-1005

Message

<timestamp>, [ANV-1005], <sequence-number>,, ERROR, <system-name>,<slot

number>,<chip index>,<anvil id>: Memory allocation failed.

Probable Cause

Indicates the memory allocation failure in the software.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the CP blade.

Severity

ERROR

ANV-1006

Message

<timestamp>, [ANV-1006], <sequence-number>,, CRITICAL, <system-name>, <slot

number>,<chip index>: HW ASIC Chip fault. Type = 0x<chip error type>, Error =

<chip error string>.

Probable Cause

Indicates an internal error in the application-specific integrated circuit (ASIC) hardware that renders
the chip as not operational.

Recommended

Action

Restart the system at the next maintenance window. If the problem persists, replace the blade.

Severity

CRITICAL

ANV-1007

Message

<timestamp>, [ANV-1007], <sequence-number>,, CRITICAL, <system-name>, <slot

number>,<chip index>: ANVIL PASS 1 low buff pool fault: <chip regval field>

0x<chip error type>.

Probable Cause

Indicates that Anvil Pass 1 is out of free buffer which might cause a chip fault.

Recommended

Action

Reconfigure the testing setup.