Fabric OS Message Reference

53-1001767-01

SEC-1167

90

SEC-1167

Message

<timestamp>, [SEC-1167], <sequence-number>,, ERROR, <system-name>, Another FCS

failover is in process. Command terminated.

Probable Cause

Indicates that because another failover is already in progress, this failover attempt cannot proceed.

Recommended

Action

Verify the security event was planned. If the security event was planned, retry fabric configurations
server (FCS) failover after current failover has completed, if this switch should become primary
FCS. If the security event was not planned, take appropriate action as defined by your enterprise
security policy.

Severity

ERROR

SEC-1168

Message

<timestamp>, [SEC-1168], <sequence-number>,, ERROR, <system-name>, Primary FCS

failover is busy. Please retry later.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configurations server (FCS) is distributing the security database to
the other switches in the fabric and local validation finds that there is an error in the security
database. This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

ERROR

SEC-1170

Message

<timestamp>, [SEC-1170], <sequence-number>,, INFO, <system-name>, This command

must be executed on the Primary FCS switch, the first reachable switch in the FCS

list.

Probable Cause

Indicates there has been a corruption during the distribution of the security database. This can only
occur when the primary fabric configuration server (FCS) is distributing the security database to the
other switches in the fabric and local validation finds that there is an error in the security database.
This is a rare occurrence.

Recommended

Action

Run the secFabricShow command to verify that the fabric is still consistent. All the switches should
be in the ready state. If a switch is in the error state, the database might not be correctly updated
for that specific switch.

Severity

INFO