Hil-1309, Hil-1310, Hil-1311 – Dell POWEREDGE M1000E User Manual

Page 452: Hil-1401

Advertising
background image

376

Fabric OS Message Reference

53-1001767-01

HIL-1309

45

Recommended

Action

Replace the faulty fan field-replaceable units (FRUs) immediately.

Severity

ERROR

HIL-1309

Message

<timestamp>, [HIL-1309], <sequence-number>,, ERROR, <system-name>,

<count>

fan

FRUs failed. Replace failed fan FRUs immediately.

Probable Cause

Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.

Recommended

Action

Replace the faulty fan field-replaceable unit (FRU)s immediately.

Severity

ERROR

HIL-1310

Message

<timestamp>, [HIL-1310], <sequence-number>,, WARNING, <system-name>,

<count>

fans faulty.

Probable Cause

Indicates that multiple fans have failed. This message is often preceded by a low fan speed
message.

Recommended

Action

Since the fans are not field replaceable, replace the switch if the temperature is high.

Severity

WARNING

HIL-1311

Message

<timestamp>, [HIL-1311], <sequence-number>,, INFO, <system-name>, No fans are

faulty.

Probable Cause

Indicates recovery from earlier condition of one or more fans having failed.

Recommended

Action

This can only occur on switches with non-removable fans. It follows a previous indication of
faultiness.

If the fan continues to generate this message, it indicates oscillation between faulty and non-faulty
behavior. Replace the switch because the fan is not field-replaceable.

Severity

INFO

HIL-1401

Message

<timestamp>, [HIL-1401], <sequence-number>,, WARNING, <system-name>, One fan FRU

missing. Install fan FRU immediately.

Advertising