Fabric OS Message Reference

53-1001767-01

HAM-1005

43

Fastboot

Giveup Master:SYSM

CP Faulty:SYSM

FirmwareDownload

ConfigDownload:MS

ChangeWWN:EM

Reboot:WebTool

Fastboot:WebTool

Software Fault:Software Watchdog

Software Fault:Kernel Panic

Software Fault:ASSERT

Reboot:SNMP

Fastboot:SNMP

Reboot

Chassis Config

Reboot:API

Reboot:HAM

EMFault:EM

Recommended

Action

Check the error log on both CPs for additional messages that might indicate the reason for the
reboot.

Severity

INFO

HAM-1005

Message

<timestamp>, [HAM-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS, INFO,

<system-name>, HeartBeat Miss reached threshold.

Probable Cause

Indicates that either the active control processor (CP) EMAC controller or the standby CP is down.
The active CP will run a diagnostic test on the EMAC controller and will wait for the standby CP to
reset it if it is down.

Recommended

Action

No action is required.

Severity

INFO

HAM-1006

Message

<timestamp>, [HAM-1006], <sequence-number>, SLOT cp-slpt-number | FFDC | CHASSIS,

FFDC, CRITICAL, <system-name>,EMAC controller for Active CP is BAD.

Probable Cause

Indicates that the local EMAC controller on the active control processor (CP) is BAD as determined
by the diagnostic test run by the HAM module.