Fabric OS Message Reference

53-1001767-01

AUTH-1022

4

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

INFO

AUTH-1022

Message

<timestamp>, [AUTH-1022], <sequence-number>,, ERROR, <system-name>, Failed to

extract <data type> from <message> payload: port <port number>.

Probable Cause

Indicates that the authentication process failed to extract a particular value from the receiving
payload.

Recommended

Action

Usually this problem is transient. The authentication might fail.

Reinitialize authentication using the portDisable and portEnable commands or the switchDisable
and switchEnable commands.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

ERROR

AUTH-1023

Message

<timestamp>, [AUTH-1023], <sequence-number>,, ERROR, <system-name>, Failed to

<operation type> during <authentication phase>: port <port number>.

Probable Cause

Indicates an authentication operation failed for a certain authentication phase.

Operation type varies depending on authentication type:

Some operations for switch link authentication protocol (SLAP): certificate retrieve, certificate
verification, signature verification, or nonce signing.

Some operations for fibre channel authentication protocol (FCAP): certificate retrieve,
certificate verification, signature verification, or nonce singing.

Some operations for Diffie Hellman - challenge handshake authentication Protocol (DH-CHAP).
response calculation, challenge generation, or secret retrieve.

The authentication phase specifies which phase of a particular authentication protocol failed.

A nonce is a single-use, usually random value used in authentication protocols to prevent replay
attacks.

Recommended

Action

The error might indicate that an invalid entity tried to connect to the switch. Check the connection
port for possible unauthorized access attack.

It might indicate that the public key infrastructure (PKI) object for SLAP or FCAP or secret value for
DH-CHAP on the local entity is not set up properly. Reinstall all PKI objects or reset the secret value
for DH-CHAP properly.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.