FW-1201
42
Probable Cause
Indicates that the number of C3 transmit time out frames has changed.
Recommended
Action
Check the target device; it could be slow.
Severity
INFO
FW-1201
Message
<timestamp>, [FW-1201], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is below low boundaries (High=<High value>, Low=<Low value>). Current
value is <Value> <Unit>.
Probable Cause
Indicates that the number of C3 transmit time out frames is below low threshold.
Recommended
Action
Respond to this message as it is appropriate to the particular policy of the end-user installation. A
low number of C3 discard means that the switch is functioning normally.
Severity
INFO
FW-1202
Message
<timestamp>, [FW-1202], <sequence-number>,, WARNING, <system-name>, <Port Name>,
<Label>, is above high boundaries (High=<High value>, Low=<Low value>). Current
value is <Value> <Unit>.
Probable Cause
Indicates that the number of C3 transmit time out frames is above high threshold.
Recommended
Action
Check the target device; it could be slow.
Severity
WARNING
FW-1203
Message
<timestamp>, [FW-1203], <sequence-number>,, INFO, <system-name>, <Port Name>,
<Label>, is between high and low boundaries (High=<High value>, Low=<Low value>).
Current value is <Value> <Unit>.
Probable Cause
Indicates that the number of C3 transmit time out frames is between high and low thresholds.
Recommended
Action
Check the target device; it could be slow.
Severity
INFO