Fabric OS Message Reference

53-1001767-01

MS-1009

69

MS-1009

Message

<timestamp>, [MS-1009], <sequence-number>,, ERROR, <system-name>, RLIR event.

Switch Port ID is <port number> (<PID (hex)>). Device Port Tag is <port tag>.

<message text>.

Probable Cause

Indicates a registered link incident record (RLIR) has been generated for one of the actions
indicated by the <message>.

The following messages will be displayed:

•

Exceeded bit error rate threshold

•

Loss of signal or synchronization

•

Not operational seq. recognized

•

Primitive sequence timeout

•

Unrecognized link incident

Recommended

Action

Persistent RLIR incidents are likely the result of SAN hardware problems such as bad cables or
small form-factor pluggables (SFPs). It may be necessary to replace hardware if these messages
persist.

Severity

ERROR

MS-1021

Message

<timestamp>, [MS-1021], <sequence-number>,, ERROR, <system-name>, MS WARMBOOT

failure(FSS_MS_WARMINIT failed. Reason=<failure reason>).

Probable Cause

Indicates the Fabric OS state synchronization (FSS) warm recovery failed during the WARM INIT
phase of a reboot.

Recommended

Action

If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the
supportSave command and contact your switch service provider.

Severity

ERROR

MS-1022

Message

<timestamp>, [MS-1022], <sequence-number>,, INFO, <system-name>, Management

Server Platform Service <Activated or Deactivated>.

Probable Cause

Indicates Management Server Platform Service is being activated or deactivated.

Recommended

Action

No action is required.

Severity

INFO