Fcph system messages, Chapter 33, Fcph-1001 – Dell POWEREDGE M1000E User Manual

Page 289: Fcph-1002, Chapter

Advertising
background image

Fabric OS Message Reference

213

53-1001767-01

Chapter

33

FCPH System Messages

FCPH-1001

Message

<timestamp>, [FCPH-1001], <sequence-number>, FFDC, CRITICAL, <system-name>,

<function>: <failed function call> failed, out of memory condition

Probable Cause

Indicates that the switch is low on memory and failed to allocate new memory for a Fibre Channel
driver instance.

The function can only be " fc_create". This function creates a Fibre Channel driver instance.

The failed function call kmalloc_wrapper has failed. This function call is for kernel memory
allocation.

Recommended

Action

A nonbladed switch will automatically reboot. For a bladed switch, the active CP blade will
automatically fail over and the standby CP will become the active CP.

Severity

CRITICAL

FCPH-1002

Message

<timestamp>, [FCPH-1002], <sequence-number>, FFDC, WARNING, <system-name>, Port

<Port Number> has been disabled since switch requires authentication when device

authentication policy is set to ON.

Probable Cause

Indicates a device which does not support authentication has tried to log in to the switch when the
device authentication policy is in ON status on the switch.

Recommended

Action

Enable the authentication on the device or set the device authentication status to PASSIVE/OFF on
the switch if it is not mandatory. Use the authUtil command to change the device authentication
policy.

Severity

WARNING

Advertising