748

Fabric OS Message Reference

53-1001767-01

SULB-1024

128

Recommended

Action

The firmwareCommit command will be started automatically after the blade boots up to repair the
secondary partition. If at the end of firmwareCommit, the blade firmware version is still
inconsistent with the active CP firmware, firmwareDownload will automatically be restarted on the
blade. Run the firmwareDownloadStatus command to monitor the progress. If the problem
persists, contact your switch service provider.

Severity

WARNING

SULB-1024

Message

AUDIT, <timestamp>, [SULB-1024], WARNING, FIRMWARE, <event-initiator-details>,

<event-location>, , Firmware commit has completed on the blade in slot

<Slot

number>.

Probable Cause

Indicates the firmwareCommit operation has completed on the specified blade.

Recommended

Action

Run the firmwareShow command to verify the firmware versions. If the blade firmware is the same
as the active CP firmware, firmwareDownload has completed successfully on the blade. However, if
the firmwareCommit operation has been started to repair the secondary partition, at the end of
firmwareCommit, the blade firmware version may still be inconsistent with the active CP firmware.
In that case, firmwareDownload will automatically be restarted on the blade. Run the
firmwareDownloadStatus command to monitor the progress.

Severity

WARNING

SULB-1026

Message

AUDIT, <timestamp>, [SULB-1026], WARNING, FIRMWARE, <event-initiator-details>,

<event-location>, , Firmware commit operation started on the blade in slot

<Slot

number>

.

Probable Cause

Indicates the firmwareCommit command has started on the specified blade. The operation may be
a normal part of firmwareDownload, or it may have started to repair the secondary partition of the
blade if the secondary partition is corrupted.

Recommended

Action

Wait for the commit operation to complete.

Severity

WARNING

SULB-1030

Message

AUDIT, <timestamp>, [SULB-1030], WARNING, FIRMWARE, <event-initiator-details>,

<event-location>, , The switch has rebooted during relocating the internal

firmware image.

Probable Cause

Indicates there may be an error caused by an unexpected disruption of the firmwareDownload
command, for example, by powering the switch off and on in the middle of a firmwareDownload.
The error may also be caused by persistent storage hardware failure or by a software error.