Fabric OS Message Reference

53-1001767-01

C2-1006

11

C2-1006

Message

Message <timestamp>, [C2-1006], <sequence-number>,, WARNING, <system-name>, <slot

number>,<chip index>: Internal link errors reported, no hardware faults

identified, continuing monitoring: fault1:<fault1_cnt>, fault2:<fault2_cnt>

thresh1:0x<threshold_used>.

Probable Cause

Indicates a warning that some internal link errors have been detected. These can be normal in an
active running system.

The system will now automatically start a more detailed monitoring of internal hardware reported
errors. There is no action required by the user at this time. If any actual hardware failures are
detected, a C2-1010 log will be generated identifying the failing FRU.

Recommended

Action

No action is required.

Severity

WARNING

C2-1007

Message

Message <timestamp>, [C2-1007], <sequence-number>,, WARNING, <system-name>, S

<slot number>, P <port number>(<blade port number>): best effort QOS will be

turned off at next port state change as it is not supported under this

configuration.

Probable Cause

Indicates QoS will be turned off automatically at the next port state change since best effort is no
longer supported on a 4G platform or 8G platform long distance port.

Recommended

Action

No action is required.

Severity

WARNING

C2-1008

Message

Message <timestamp>, [C2-1008], <sequence-number>,, WARNING, <system-name>, <slot

number>, <port number><blade port number>: QOS overwrites portcfglongdistance

vc_translation_link_init. ARB will be used on the link.

Probable Cause

Indicates QoS overwrites the portcfglongdistance vc_translation_link_init 0 choice. ARB will be
used on the link.

Recommended

Action

No action is required.

Severity

WARNING