Fabric OS Message Reference

241

53-1001767-01

FICN-1007

35

FICN-1007

Message

<timestamp>, [FICN-1007], <sequence-number>,, ERROR, <system-name>,

DevDiskEgr:FICON Selective Reset:Path=<VEPortNumber HostDomain HostPort

DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> State=0x<current Emulation

State> stat_array=0x<last 4 Status values that were received from the device>.

Probable Cause

Indicates a Selective Reset from the channel was received as either a normal part of path recovery
or starting sequence in an error case.

Recommended

Action

If there was a job failure associated with this event, please contact your vendor's customer support.

Severity

ERROR

FICN-1008

Message

<timestamp>, [FICN-1008], <sequence-number>,, ERROR, <system-name>,

DevDiskEgr:FICON Purge Path received Path=<VEPortNumber HostDomain HostPort

DeviceDomcontactain> <DevicePort LPAR CUADDR DeviceAddr>.

Probable Cause

Indicates a FICON Purge Path was received from the channel as a part of path recovery.

Recommended

Action

If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.

Severity

ERROR

FICN-1009

Message

<timestamp>, [FICN-1009], <sequence-number>,, INFO, <system-name>,

DevIng:CmdReject Sense Data rcvd:Path=<VEPortNumber HostDomain HostPort

DeviceDomain> <DevicePort LPAR CUADDR DeviceAddr> <Current Emulation State>

LastCmds=<the Last 4 commands issued to the device> Sense Data:Bytes0-0xB=<bytes

0-3 of sense data from the device> <bytes 4-7 of sense data from the device>

<bytes 8-0x0b of sense data from the device>.

Probable Cause

Indicates a Unit Check status was received from a device and a sense command was issued to
read the sense data.

Recommended

Action

If there was a job failure associated with this event, please contact your vendor's customer support
for assistance.

Severity

INFO

FICN-1010

Message

<timestamp>, [FICN-1010], <sequence-number>,, INFO, <system-name>,

DevDiskEgr:Device level exception flag found for Path=<VEPortNumber HostDomain

HostPort DeviceDomain>8X<DevicePort LPAR CUADDR DeviceAddr>8X: Oxid=0x<The OXID

that was reported in the Device Level Exception Frame>4X.