Fabric OS Message Reference

379

53-1001767-01

HIL-1505

45

Recommended

Action

No action is required.

Severity

INFO

HIL-1505

Message

<timestamp>, [HIL-1505], <sequence-number>,, WARNING, <system-name>, High

temperature (<measured temperature> C) fan speed increasing per environmental

specifications.

Probable Cause

Indicates that temperatures in the system have risen above the warning threshold and the fan
speed is increased.

Recommended

Action

Run the fanShow command to verify all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

WARNING

HIL-1506

Message

<timestamp>, [HIL-1506], <sequence-number>, FFDC, CRITICAL, <system-name>, High

temperature (<measured temperature> C) exceeds system temperature limit. System

will shut down within 2 minutes.

Probable Cause

Indicates that temperatures in the system have risen above the critical threshold.

Recommended

Action

Run the fanShow command to verify that all fans are working properly. Replace any deteriorating
fan field-replaceable units (FRUs).

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

CRITICAL

HIL-1507

Message

<timestamp>, [HIL-1507], <sequence-number>, FFDC, CRITICAL, <system-name>, High

temperature warning time expired. System preparing for shutdown.

Probable Cause

Indicates that temperatures in the system have risen above the critical threshold.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.