Ficn-1082, Ficn-1083, Ficn-1084 – Dell POWEREDGE M1000E User Manual

Page 339: Ficn-1085

Advertising
background image

Fabric OS Message Reference

263

53-1001767-01

FICN-1082

35

Recommended

Action

This is normally an unexpected event, contact your vendor's customer support for assistance.

Severity

WARNING

FICN-1082

Message

<timestamp>, [FICN-1082], <sequence-number>,, WARNING, <system-name>,

EmulEls:CSWR_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>

Domain=0x<Domain Port Host> Port=0x<Device Side>.

Probable Cause

Indicates an attached port which had a FICON emulated path established has logged out from the
switch.

Recommended

Action

This may be an unexpected event, contact your vendor's customer support for assistance.

Severity

WARNING

FICN-1083

Message

<timestamp>, [FICN-1083], <sequence-number>,, WARNING, <system-name>,

EmulEls:SW_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>

Domain=0x<Domain Port Host> Port=0x<Device Side>.

Probable Cause

Indicates an attached port with the established FICON emulated path has logged out from the
switch.

Recommended

Action

This may be an unexpected event, contact your vendor's customer support for assistance.

Severity

WARNING

FICN-1084

Message

<timestamp>, [FICN-1084], <sequence-number>,, ERROR, <system-name>, fcFicInit: No

DRAM2 memory available, FICON emulation is disabled.

Probable Cause

Indicates a faulty DRAM2 was detected and access to its address range is prohibited.

Recommended

Action

This is an unexpected event, contact your vendor's customer support for assistance.

Severity

ERROR

FICN-1085

Message

<timestamp>, [FICN-1085], <sequence-number>,, INFO, <system-name>, FICON FCIP

Tunnel is Up on GE<Either GE0 or GE1>,tunnel Id=<The configured tunnel ID (0-7)>.

Advertising