Ficn-1082, Ficn-1083, Ficn-1084 – Dell POWEREDGE M1000E User Manual
Page 339: Ficn-1085
Fabric OS Message Reference
263
53-1001767-01
FICN-1082
35
Recommended
Action
This is normally an unexpected event, contact your vendor's customer support for assistance.
Severity
WARNING
FICN-1082
Message
<timestamp>, [FICN-1082], <sequence-number>,, WARNING, <system-name>,
EmulEls:CSWR_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause
Indicates an attached port which had a FICON emulated path established has logged out from the
switch.
Recommended
Action
This may be an unexpected event, contact your vendor's customer support for assistance.
Severity
WARNING
FICN-1083
Message
<timestamp>, [FICN-1083], <sequence-number>,, WARNING, <system-name>,
EmulEls:SW_RSCN received on GEPort=<GEPortNumber> VEPort=<VEPortNumber>
Domain=0x<Domain Port Host> Port=0x<Device Side>.
Probable Cause
Indicates an attached port with the established FICON emulated path has logged out from the
switch.
Recommended
Action
This may be an unexpected event, contact your vendor's customer support for assistance.
Severity
WARNING
FICN-1084
Message
<timestamp>, [FICN-1084], <sequence-number>,, ERROR, <system-name>, fcFicInit: No
DRAM2 memory available, FICON emulation is disabled.
Probable Cause
Indicates a faulty DRAM2 was detected and access to its address range is prohibited.
Recommended
Action
This is an unexpected event, contact your vendor's customer support for assistance.
Severity
ERROR
FICN-1085
Message
<timestamp>, [FICN-1085], <sequence-number>,, INFO, <system-name>, FICON FCIP
Tunnel is Up on GE<Either GE0 or GE1>,tunnel Id=<The configured tunnel ID (0-7)>.