Fabric OS Message Reference

593

53-1001767-01

Chapter

95

SS System Messages

SS-1000

Message

<timestamp>, [SS-1000], <sequence-number>,, INFO, <system-name>, supportSave has

uploaded support information to the host with IP address <host ip>.

Probable Cause

Indicates the supportSave command was used to transfer support information to a remote
location.

Recommended

Action

No action is required.

Severity

INFO

SS-1001

Message

<timestamp>, [SS-1001], <sequence-number>,, WARNING, <system-name>, supportSave's

upload operation to host IP address <host ip> aborted.

Probable Cause

Indicates a file copy error has occurred during execution of the supportSave command. Complete
error information cannot always be displayed in this message due to possible errors in
subcommands being executed by the supportSave command.

Recommended

Action

Check the remote server settings. Run the supportFtp command to set the FTP or SCP parameters.
After the problem is corrected, rerun the supportSave command.

Severity

WARNING

SS-1002

Message

<timestamp>, [SS-1002], <sequence-number>,, INFO, <system-name>, supportSave has

stored support information to the USB storage device.

Probable Cause

Indicates the supportSave command was used to transfer support information to an attached USB
storage device.

Recommended

Action

No action is required.

Severity

INFO