Swch-1011, Swch-1012, Swch-1013 – Dell POWEREDGE M1000E User Manual

Page 702: Swch-1014

Advertising
background image

626

Fabric OS Message Reference

53-1001767-01

SWCH-1011

98

Severity

WARNING

SWCH-1011

Message

<timestamp>, [SWCH-1011], <sequence-number>,, WARNING, <system-name>, HA state

out of sync: Standby CP (ver = <standby SWC version>) does not support Trunk Area

functionality. (active ver = <active SWC version>, Trunk Area enabled on switch =

<'1' if Trunk Area ports exist; Otherwise '0'>).

Probable Cause

Indicates the standby control processor (CP) does not support Trunk Area functionality, but the
switch has some ports with Trunk Area enabled.

Recommended

Action

Load a firmware version on standby that supports Trunk Area functionality, using the
firmwareDownload command.

Severity

WARNING

SWCH-1012

Message

<timestamp>, [SWCH-1012], <sequence-number>,, INFO, <system-name>, Trunk Area

(<trunk area>) has been enabled for one or more ports).

Probable Cause

Indicates that a Trunk Area has been enabled for one or more ports and the configuration file has
been updated.

Recommended

Action

No action is required.

Severity

INFO

SWCH-1013

Message

<timestamp>, [SWCH-1013], <sequence-number>,, INFO, <system-name>, Trunk Area has

been disabled for one or more ports.

Probable Cause

Indicates that a Trunk Area assignment has been disabled for one or more ports and the
configuration file has been updated.

Recommended

Action

No action is required.

Severity

INFO

SWCH-1014

Message

<timestamp>, [SWCH-1014], <sequence-number>,, INFO, <system-name>, All Trunk

Areas have been disabled.

Probable Cause

Indicates that all Trunk Areas have been disabled and the configuration file has been updated.

Advertising