464

Fabric OS Message Reference

53-1001767-01

PDM-1022

75

Probable Cause

Indicates a system call failed.

Recommended

Action

Run the firmwareDownload command to reinstall the firmware.

If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.

Severity

WARNING

PDM-1022

Message

<timestamp>, [PDM-1022], <sequence-number>,, WARNING, <system-name>, The switch

is configured only with IPv6.

Probable Cause

Indicates that the parity data manager (PDM) cannot synchronize with its peer because the
firmware does not support IPv6.

Recommended

Action

Configure the local switch with IPv4 addresses.

Severity

WARNING

PDM-1023

Message

<timestamp>, [PDM-1023], <sequence-number>,, WARNING, <system-name>, Radius is

configured for IPv6.

Probable Cause

Indicates that the parity data manager (PDM) cannot synchronize with its peer because the Radius
server is configured for IPv6 addresses. IPv6 is not supported by older firmware.

Recommended

Action

Configure the Radius server with IPv4 addresses.

Severity

WARNING

PDM-1024

Message

<timestamp>, [PDM-1024], <sequence-number>,, WARNING, <system-name>, DNS is

configured for IPv6.

Probable Cause

Indicates that the parity data manager (PDM) cannot synchronize with its peer because the domain
name service (DNS) is configured for IPv6. IPv6 is not supported by older firmware.

Recommended

Action

Configure DNS with IPv4 addresses.