Spc system messages, Chapter 93, Spc-1001 – Dell POWEREDGE M1000E User Manual

Page 647: Spc-1002, Spc-1003, Chapter

Advertising
background image

Fabric OS Message Reference

571

53-1001767-01

Chapter

93

SPC System Messages

SPC-1001

Message

<timestamp>, [SPC-1001], <sequence-number>,, INFO, <system-name>, <slot number

containing Encryption Engine>, Cryptographic operation enabled.

Probable Cause

Indicates the cryptographic operation is enabled on an encryption engine.

Recommended

Action

No action is required.

Severity

INFO

SPC-1002

Message

<timestamp>, [SPC-1002], <sequence-number>,, INFO, <system-name>, <slot number

containing Encryption Engine>, Cryptographic operation disabled.

Probable Cause

Indicates the cryptographic operation is disabled on an encryption engine.

Recommended

Action

No action is required.

Severity

INFO

SPC-1003

Message

<timestamp>, [SPC-1003], <sequence-number>,, ERROR, <system-name>, <slot number

containing Encryption Engine>, Security Processor faulted.

Probable Cause

Indicates the security processor is faulted because of an internal error. Cryptographic operations
are affected.

Recommended

Action

For a bladed system, perform slotpoweroff and slotpoweron commands on the blade to recover the
system. For a non-bladed system, perform a fastboot command on the switch to recover the
system.

Severity

ERROR

Advertising