Fabric OS Message Reference

79

53-1001767-01

BM-1007

10

BM-1007

Message

<timestamp>, [BM-1007], <sequence-number>,, INFO, <system-name>, If set, clear

EX/VEX/FC Fastwrite configuration for all ports for blade in slot <Slot number>

.

Probable Cause

Indicates the specified blade was detected for the first time after an FR4-18i was previously
configured in the same slot. The new blade requires the specified port configurations to be cleared.

Recommended

Action

No action is required. The blade ports are cleared automatically.

Severity

INFO

BM-1008

Message

<timestamp>, [BM-1008], <sequence-number>,, WARNING, <system-name>, Download of

blade firmware failed for blade in slot <slot>

.

Reissue firmwaredownload to

recover.

Probable Cause

Indicates the automatic firmware upgrade on the blade has failed, because the blade firmware
version was detected to be different from the control processor (CP) firmware version due to a
firmware upgrade.

Recommended

Action

Issue the firmwareDownload command to recover the blade.

Severity

WARNING

BM-1009

Message

<timestamp>, [BM-1009], <sequence-number>,, WARNING, <system-name>,

Firmwaredownload timed-out for application processor. Faulting switch.

Probable Cause

Indicates the firmwareDownload on the application processor (AP) blade failed.

Recommended

Action

Use the slotPowerOff and slotPowerOn commands or reseat the affected blade. On the Brocade
7500 or 7600, switch off and switch on all primary power in order to power-cycle the unit.

Severity

WARNING

BM-1010

Message

<timestamp>, [BM-1010], <sequence-number>,, INFO, <system-name>, Resetting port

configuration and linkcost for all ports for blade in slot <Slot number>.

Probable Cause

Indicates the specified blade was detected for the first time after an FC10-6 was previously
configured in the same slot. The new blade requires resetting the port configuration and linkcost.

Recommended

Action

No action is required. The blade ports are cleared automatically.