background image

Fabric OS Message Reference

345

53-1001767-01

FW-1438

42

FW-1438

Message

<timestamp>, [FW-1438], <sequence-number>,, WARNING, <system-name>, Switch status

change contributing factor Missing SFPs:

<Num of missing SFPs>

missing SFPs.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the number of
missing small form-factor pluggables (SFPs) is greater than or equal to the policy set by the
switchStatusPolicySet command.

Recommended

Action

Run the switchStatusPolicySet command to modify the SFP policy or to add SFPs to the empty
ports.

Severity

WARNING

FW-1439

Message

<timestamp>, [FW-1439], <sequence-number>,, WARNING, <system-name>, Switch status

change contributing factor Switch offline.

Probable Cause

Indicates that the switch status is not in a healthy state. This occurred because the switch is
offline.

Recommended

Action

Run the switchEnable command.

Severity

WARNING

FW-1440

Message

<timestamp>, [FW-1440], <sequence-number>,, INFO, <system-name>, <FRU label>

state has changed to <FRU state>.

Probable Cause

Indicates that the state of the specified field-replaceable unit (FRU) has changed to “absent”.

Recommended

Action

No action is required. Verify that the event was planned.

Severity

INFO

FW-1441

Message

<timestamp>, [FW-1441], <sequence-number>,, INFO, <system-name>, <FRU label>

state has changed to <FRU state>.

Probable Cause

Indicates that the state of the specified field-replaceable unit (FRU) has changed to “inserted”. This
means that an FRU is inserted but not powered on.

Recommended

Action

No action is required. Verify that the event was planned.