Snmp-1004, Snmp-1005, Snmp-1006 – Dell POWEREDGE M1000E User Manual

Page 644: Snmp-1007

Advertising
background image

568

Fabric OS Message Reference

53-1001767-01

SNMP-1004

92

SNMP-1004

Message

<timestamp>, [SNMP-1004], <sequence-number>, FFDC, ERROR, <system-name>,

Incorrect SNMP configuration.

Probable Cause

Indicates the simple network management protocol (SNMP) configuration is incorrect and the
SNMP service will not work correctly.

Recommended

Action

Change the SNMP configuration back to the default.

Severity

ERROR

SNMP-1005

Message

<timestamp>, [SNMP-1005], <sequence-number>, AUDIT, INFO, <system-name>, SNMP

configuration attribute, <Changed attribute>, has changed from <Old Value> to <New

Value>

Probable Cause

Indicates the simple network management protocol (SNMP) configuration has changed. The
parameter that was modified is displayed as well as the old and new values for that parameter.

Recommended

Action

Execute the snmpConfig --show command to see the new configuration.

Severity

INFO

SNMP-1006

Message

<timestamp>, [SNMP-1006], <sequence-number>, AUDIT, INFO, <system-name>, <SNMP

Configuration group> configuration was reset to default

Probable Cause

Indicates the simple network management protocol (SNMP) configuration group was reset to the
factory default.

Recommended

Action

Execute the snmpConfig --show for the group to see the new configuration.

Severity

INFO

SNMP-1007

Message

<timestamp>, [SNMP-1007], <sequence-number>,, INFO, <system-name>, The last

fabric change happened at: <string>.

Probable Cause

Indicates the last fabric change time.

Recommended

Action

Execute the fabricshow command to view the current fabric status.