Snmp-1004, Snmp-1005, Snmp-1006 – Dell POWEREDGE M1000E User Manual
Page 644: Snmp-1007
568
Fabric OS Message Reference
53-1001767-01
SNMP-1004
92
SNMP-1004
Message
<timestamp>, [SNMP-1004], <sequence-number>, FFDC, ERROR, <system-name>,
Incorrect SNMP configuration.
Probable Cause
Indicates the simple network management protocol (SNMP) configuration is incorrect and the
SNMP service will not work correctly.
Recommended
Action
Change the SNMP configuration back to the default.
Severity
ERROR
SNMP-1005
Message
<timestamp>, [SNMP-1005], <sequence-number>, AUDIT, INFO, <system-name>, SNMP
configuration attribute, <Changed attribute>, has changed from <Old Value> to <New
Value>
Probable Cause
Indicates the simple network management protocol (SNMP) configuration has changed. The
parameter that was modified is displayed as well as the old and new values for that parameter.
Recommended
Action
Execute the snmpConfig --show command to see the new configuration.
Severity
INFO
SNMP-1006
Message
<timestamp>, [SNMP-1006], <sequence-number>, AUDIT, INFO, <system-name>, <SNMP
Configuration group> configuration was reset to default
Probable Cause
Indicates the simple network management protocol (SNMP) configuration group was reset to the
factory default.
Recommended
Action
Execute the snmpConfig --show for the group to see the new configuration.
Severity
INFO
SNMP-1007
Message
<timestamp>, [SNMP-1007], <sequence-number>,, INFO, <system-name>, The last
fabric change happened at: <string>.
Probable Cause
Indicates the last fabric change time.
Recommended
Action
Execute the fabricshow command to view the current fabric status.