Hil-1508, Hil-1509, Hil-1510 – Dell POWEREDGE M1000E User Manual

Page 456

Advertising
background image

380

Fabric OS Message Reference

53-1001767-01

HIL-1508

45

Severity

CRITICAL

HIL-1508

Message

<timestamp>, [HIL-1508], <sequence-number>, FFDC, CRITICAL, <system-name>, Fan

faulty warning time expired. System preparing for shutdown.

Probable Cause

Indicates that temperatures in the system have remained above the critical threshold too long.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

CRITICAL

HIL-1509

Message

<timestamp>, [HIL-1509], <sequence-number>, FFDC, CRITICAL, <system-name>, High

temperature (<measured temperature> C). Warning time expired. System preparing for

shutdown.

Probable Cause

Indicates that temperatures in the system have risen above the critical threshold.

Recommended

Action

To avoid causing damage to the switch, the system shuts down automatically. To help prevent
future problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

CRITICAL

HIL-1510

Message

<timestamp>, [HIL-1510], <sequence-number>,, WARNING, <system-name>, Current

temperature (<measured temperature> C) is below shutdown threshold. System

shutdown cancelled.

Probable Cause

Indicates that temperatures in the system have dropped below the critical threshold; the system
can continue operation.

Recommended

Action

To help prevent future problems, make sure that all the fans are working properly.

Make sure that the area is well-ventilated and that the room temperature is within operational
range of your switch. Refer to the hardware reference manual for your switch for the operational
temperature range.

Severity

WARNING

Advertising