Fabric OS Message Reference
115
53-1001767-01
CNM-3011
16
Recommended
Action
No action is required.
Severity
INFO
CNM-3011
Message
<timestamp>, [CNM-3011], <sequence-number>,, INFO, <system-name>, Event:
cryptocfg Status: success, Info: Encryption group synchronized.
Probable Cause
Indicates an encryption group was synchronized.
Recommended
Action
No action is required.
Severity
INFO
CNM-3012
Message
<timestamp>, [CNM-3012], <sequence-number>,, INFO, <system-name>, Deleteing an EG
with luns setup for encryption can lead to luns being disabled if Encryption Group
name is not preserved (<egname>).
Probable Cause
Indicates that the Encryption Group (EG) was deleted, recreate EG with the same name if luns are
setup for encryption.
Recommended
Action
Preserve EG name when EG is recreated if luns are setup for encryption.
Severity