Fss-1004, Fss-1005, Fss-1006 – Dell POWEREDGE M1000E User Manual

Page 358: Fss-1007

Advertising
background image

282

Fabric OS Message Reference

53-1001767-01

FSS-1004

40

If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

WARNING

FSS-1004

Message

<timestamp>, [FSS-1004], <sequence-number>, SLOT cp-slot-number | CHASSIS, ERROR,

<system-name>, Memory shortage

Probable Cause

Indicates that the system ran out of memory.

Recommended

Action

Run the memShow command to view memory usage.

Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed
system.

If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

ERROR

FSS-1005

Message

<timestamp>, [FSS-1005], <sequence-number>, SLOT cp-slot-number | CHASSIS,

WARNING, <system-name>, FSS read failure

Probable Cause

Indicates that the read system call to the Fabric OS state synchronization (FSS) device failed.

Recommended

Action

If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

WARNING

FSS-1006

Message

<timestamp>, [FSS-1006], <sequence-number>, SLOT cp-slot-number | CHASSIS,

WARNING, <system-name>, No FSS message available

Probable Cause

Indicates that data is not available on the Fabric OS state synchronization (FSS) device.

Recommended

Action

If the message persists, run the supportFtp (as needed) to set up automatic FTP transfers; then run
the supportSave command and contact your switch service provider.

Severity

WARNING

FSS-1007

Message

<timestamp>, [FSS-1007], <sequence-number>, SLOT cp-slot-number | CHASSIS,

CRITICAL, <system-name>,

<component name>

: Faulty Ethernet connection.

Advertising